Indoor Air Quality Solutions Blog

"Healthier Air Starts Here" (407) 383-9459




Indoor Air Quality IAQ Blog





Chemical Free Mold Remediation

Orlando Mold InspectionMold Remediation is the process of removing mold while protecting unaffected areas of a home or office from unnecessary cross contamination.  At no time is it necessary to KILL Mold.  Mold must be Removed regardless of its ability to germinate and grow into a colony.  The safest way to end the life cycle of mold is to simply eliminate the water source that is allowing the mold to grow.  Removing the water source is far safer that using Biocides and you will still need to remove the mold regardless of the molds viability.

So Remember ALL Mold Remediation Should be Chemical Free Mold Remediation.

The Florida Department of Health
The goal should be to remove mold growth by cleaning or removing moldy materials. Dead mold can still pose health risks if you are exposed.

Ozone irritates lungs, and is not likely to be effective at addressing an indoor mold problem. No one should expose themselves or others to ozone on purpose. Address the cause of the mold (usually moisture) and then remove the mold by cleaning surfaces or removing moldy materials.

We know that we’ll never be able to eliminate all of the mold from within our home or office.  But we can prevent it from growing within our home or office by eliminating the moisture that supports its growth.  The sources of moisture that support mold growth include elevations of humidity above 60%, plumbing leaks, and building envelope failure such as roof and window leaks.

If mold is found to be growing in your home or office due to an elevation in humidity, leak, or an unfortunate water loss, you need to first identify the moisture source that is supporting the mold growth to correct and prevent continued mold growth. Then, collect and remove the mold and water damaged building material from the indoor environment.

Mold only needs a few things to grow and multiply:

    Nutrients (food – almost anything)
    A suitable place to grow (almost anywhere)
    Moisture

Eliminating any one will prevent the mold from growing.  What you’re left with is the mold that can become airborne and directly affect the occupants.  This mold must be collected and removed from your home or office.

We know that there is no shortage of “Quick Fix” Ozone or Chemical using mold remediators out there that will chemically fog your home or office and affordably “Kill” your mold, but guess what?  Your mold is still there.  Without the moisture you corrected the mold wouldn’t have regrown anyway.  Now you have the mold (allergen) covered in a chemical (poisonous both to the mold and humans) and is now a “poisonous allergen” waiting to become airborne and potentially impact the occupants.

There is no need to expose anyone to Ozone, Hydroxyls, Biocides, Disinfectants, Fungicides, Anti-microbials, and Encapsulants during Mold Remediation.

Our Mold Remediation Protocols are written to protect or clients from the dust up of mold during the removal and the unnecessary use of chemicals.  Our Protocols are designed to collect and remove the mold from your home or office without the use of chemicals.

Our goal is to protect our Clients from exposure to Ozone, Hydroxyls, Biocides, Disinfectants, Fungicides, Anti-microbials, and Encapsulants during Mold Remediation.  The unnecessary use of these products are Forbiden.

All of our Mold Remeiation Protocols include the following statement:

Ozone, Hydroxyls, Biocides, Disinfectants, se Fungicides, Anti-microbials, and Encapsulants must not be used unless specified in this protocol.  If chemical use is specified in this protocol, the chemicals can only be applied in the specific areas identified in this protocol.

If chemical use is specified in this protocol the chemicals will be used for the purpose of Disinfection of the Category 3 water damaged areas and not for the purpose of Killing or Removing Mold.

If the remediation contractor would like to apply chemicals in any way not specified in this protocol, the Remediator must obtain written permission from the IAQ Solutions IEP.

IICRC S-520
Source removal of mold contamination should always be the primary means of remediation.  The Indiscriminant use of antimicrobial products, coatings, sealants, and cleaning chemicals is not recommended.

NYCDH New York City Department of Health
"The use of gaseous, vapor-phase, or aerosolized biocides for remedial purposes is not recommended. The use of biocides in this manner can pose health concerns for people in occupied spaces of the building and for people returning to the treated space if used improperly.

AIHA American Industrial Hygiene Association
The goal of remediation is removal of mold and the moisture source because:


  • biocides do not alter mycotoxins or allergens;
  • it is generally not possible to get 100 percent kill with biocides; and
  • the newly deposited spores, re-growth will occur after the biocides if moisture returns

OSHA Occupational Safety and Health Administration
The use of a biocide, such as chlorine bleach, is not recommended as a routine practice during mold remediation, although there may be instances where professional judgment may indicate its use (for example, when immuno-compromised individuals are present). In most cases, it is not possible or desirable to sterilize an area, as a background level of mold spores comparable to the level in outside air will persist. However, the spores in the ambient air will not cause further problems if the moisture level in the building has been corrected. Biocides are toxic to animals and humans, as well as to mold.

U.S. EPA Environmental Protection Agency
"The purpose of mold remediation is to remove the mold to prevent human exposure and damage to building materials and furnishings. It is necessary to clean up mold contamination, not just to kill the mold. Dead mold is still allergenic, and some dead molds are potentially toxic.  Whether dead or alive, mold is allergenic, and some molds may be toxic.




Add a Comment

(Enter the numbers shown in the above image)


Follow jlapotaire on Twitter


Review microshield-es.com on alexa.com
   

[Valid RSS]
Add this Content to Your Site
   


Latest Top (12) News


EPISODE511: Chuck Violand, Ross Riek, Owen Boak and The Restoration Global Watchdog!
This past June RIA held its first International restoration conference and trade show on Australia’s beautiful Sunshine Coast. The event which will be an annual offering in the region was organized and delivered by RIA’s Australasian Council. The local RIA conference planning committee collaborated with the Australian IAQA chapter leadership and featured several education sessions by local leading IAQ experts. Mold seemed to be a hot topic at the conference with several labs exhibiting at the trade show! The event was also attended by IICRC leadership and several other regional dignitaries from related segments of the cleaning, restoration and remediation industries.

Thu, 03 Jan 2019 13:00:00 -0800


EPISODE497 - Radio Joe and the Z-man – Using Building Science & EPA’s Moisture Control Guide to Improve Indoor Air!
Today Radio Joe and the Z-man will be discussing how to solve indoor environmental quality problems by using building science fundamentals and the “EPA Moisture Control Guide”. To get at the root of IEQ problems you must understand buildings and building science. Today we will discuss some great information from people like Joe Lstiburek, Terry Brennan, Bill Rose, Mike McGuinness and Lew Harriman. We start with an overview of building science concepts that will help you solve problems. Our foundation will be the 4 P’s (people, pollutant, pathway, pressurization). From there we will go into how to use the wealth of information in the EPA “Moisture Control Guide” and then go through some case studies. On a future show we will get into how to include the information in your reports

Thu, 11 Oct 2018 09:00:00 -0700


EPISODE 517: Steven M. Spivak, PhD – Professor Emeritus, Univ. of Maryland – An Interview with Industry Icon: Reflections spanning half a century of advising the world-wide Cleaning & Restoration Community


Fri, 21 Sep 2018 10:00:00 -0700


EPISODE 517: Steven M. Spivak, PhD – Professor Emeritus, Univ. of Maryland – An Interview with Industry Icon: Reflections spanning half a century of advising the world-wide Cleaning & Restoration Community


Fri, 21 Sep 2018 10:00:00 -0700


EPISODE 516: Mike O’Donnell – Ben Umberger – Assessment & Restoration of Contents Affected by Smoke, Water, Mold & other Contaminates


Fri, 14 Sep 2018 10:00:00 -0700


EPISODE 515: Don Weekes, CIH, CSP – IEQ Current Events Discussion


Fri, 07 Sep 2018 10:00:00 -0700


EPISODE 515: Don Weekes, CIH, CSP – IEQ Current Events Discussion


Fri, 07 Sep 2018 10:00:00 -0700


EPISODE 514: IAQ Radio Classic: Pete Consigli & The Z-man – A History of the Restoration Industry Parts 1-3


Fri, 24 Aug 2018 10:00:00 -0700


EPISODE 513: FLASHBACK FRIDAY – Ellen Tohn – Tohn Environmental Strategies Health and Home Performance: A Game Changer – Original Air Date: Episode 457 | 4-21-17


Fri, 17 Aug 2018 08:45:00 -0700


EPISODE512: FLASHBACK FRIDAY – Paul Francisco – University of Illinois at Urbana-Champaign – Ventilation and IAQ – EPISODE 448 (Air Date: 2-17-2017)
Paul Francisco runs The Indoor Climate Research and Training Group at The Applied Research Institute of the University of Illinois, Urbana-Champaign. He does both research and training on issues related to home performance, and his research focuses on indoor air quality, energy efficiency and emphasizing field measurements. His training focuses on teaching practitioners building diagnostics and Health and Safety. He’s also been a trainer in that area in the home weatherization assistance program. He’s done extensive work on curriculum development for weatherization workers and also research on energy efficiency and indoor air quality in existing homes. He is also the current Chair of the ASHRAE 62.2 Ventilation and Acceptable Indoor Quality in Residential Buildings. He’s got his Bachelors degree from University of Delaware and a Masters in Mechanical Engineering from the University of Washington

Fri, 03 Aug 2018 13:00:00 -0700


EPISODE512: FLASHBACK FRIDAY – Paul Francisco – University of Illinois at Urbana-Champaign – Ventilation and IAQ – EPISODE 448 (Air Date: 2-17-2017)
Paul Francisco runs The Indoor Climate Research and Training Group at The Applied Research Institute of the University of Illinois, Urbana-Champaign. He does both research and training on issues related to home performance, and his research focuses on indoor air quality, energy efficiency and emphasizing field measurements. His training focuses on teaching practitioners building diagnostics and Health and Safety. He’s also been a trainer in that area in the home weatherization assistance program. He’s done extensive work on curriculum development for weatherization workers and also research on energy efficiency and indoor air quality in existing homes. He is also the current Chair of the ASHRAE 62.2 Ventilation and Acceptable Indoor Quality in Residential Buildings. He’s got his Bachelors degree from University of Delaware and a Masters in Mechanical Engineering from the University of Washington

Fri, 03 Aug 2018 13:00:00 -0700


EPISODE508: HOMEChem Open House – House Observations of Microbial and Environmental Chemistry
This week on IAQradio+ will be broadcasting live from the Open House event for the HOMEChem study at the University of Texas Austin’s, J.J. Pickle Research Campus. The HOMEChem experiment (House Observations of Microbial and Environmental Chemistry) incorporates state-of-the-art measurements performed by over 20 investigators and their teams from the fields of chemistry, microbiology, and engineering. This experiment engages far more institutions and disciplines than ever applied to the study of a home. This research study is sponsored by the Alfred P. Sloan Foundation Chemistry of Indoor Environments Program and it will take place this summer at the University of Texas at Austin’s UTest House. Our guests for this special show are Marina Vance (HOMEChem Co-PIs / organizer) Delphine Farmer (HOMEChem Co-PIs / organizer) Atila Novoselac (HOMEChem host, specialist on the UTest house) Rich Corsi (HOMEChem host, indoor air specialist) Dr. Richard L. Corsi is the Joe J. King Chair in Engineering #2 in the Department of Civil, Architectural and Environmental Engineering (CAEE) at The University of Texas at Austin (UT Austin). He has served on the faculty of CAEE at UT Austin for nearly 25 years, after starting his career in the School of Engineering at the University of Guelph in Ontario, Canada. Dr. Corsi is highly regarded as an educator. He has received numerous teaching awards, and in 2015 was inducted into the Academy of Distinguished Teachers, an honor held for the top 5% of teachers across UT Austin. He also received a Regents’ Outstanding Teaching Award for the entire UT system in 2016. Dr. Corsi’s research focuses on sources, physics and chemistry of indoor air pollution, particularly as related to pollutant interactions with indoor materials and innovative strategies for using such interactions to reduce human exposure to air pollution of both outdoor and indoor origin. He has served as principal investigator on over 70 projects, as major advisor to over 50 undergraduate and 70 graduate students, and as co-author on over 300 journal/conference papers, reports, and book chapters. His work has been featured in National Geographic, The Economist, Business Week, National Wildlife, Prevention, Men’s Health, National Public Radio’s Science Friday, Science Studio, the Academic Minute, the Canadian television series The Nature of Things, and more. Delphine Farmer, PhD Dr. Delphine Farmer is an Associate Professor in the Department of Chemistry at Colorado State

Fri, 22 Jun 2018 13:30:00 -0700
Follow Microshields IAQ News and Headlines Bloglines RSS Feed

Subscribe with Bloglines

 



IAQ News and Articles

Latest Top (10) News
http://recordings.talkshoe.com/rss1547.xml